Disclaimer
Failure to comply with the following steps will result in a void of the manufacturer’s warranty. The dealer/ installer will be responsible for all costs associated with failure to comply, including replacement parts, and/ or additional on-site visits needed for repair work.
Zero G: Overview - Please Review before installation.
- The upper limit will be set from the factory.
- If the upper limit needs to be adjusted, follow these steps
Step 1:
- Remove the board from the enclosure.
Step 2:
- Disconnect the motor from the board
Step 3:
- Connect the motor directly to the MOTOR ONLY side of the MOAB.
Step 4:
- Ensure all DIP switches are in the ON (up) position.
- If pairing is required, press and hold the Green Button until the Green LED flashes and the 485 Pairing LED turns OFF.
Step 5:
Adjust the Upper Limit:
- Use the RED/UP and BLUE/DOWN buttons to position the screen at the desired upper limit.
- Press and hold both the RED and GREEN buttons until their LEDs flash. Release to save the upper limit.
Step 6:
Switching to User Mode
- Move Dip Switch #1 into the OFF position.
Step 7:
- Re-connect the motor to the board.
Step 8:
- Close the Control Panel. Carefully push up the control center back into the tray ensuring the cables or 4 motherboard are not damaged.
-
Tighten panel fastening screws.
- Do not force the control panel. If it does not close easily, reopen the panel and look for wires or other obstructions and then attempt to close it again.
For issues, contact Screen Innovations:
Phone: 512.832.6939 Option 3
Website: www.screeninnovations.com