Installation
Instructions that must be followed by the drive and home automation professional installing the Glydea Ultra motor.
Never drop, knock, drill, or submerge the drive.
Install a separate control point for each drive.
Wiring
Cables that pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
Leave the drive power supply cable accessible — it must be possible to replace it easily.
Steps:
Switch off the power supply.
Connect the drive according to the information in the table below.
Compatible Controls – Wiring of Control
RS485(SDN) Moudul
Zigbee Module
2 NO (Normally Open) dry contact switch
Installation
Installation of the Rail
Mark the position of the brackets.
Drill the ceiling or wall at the correct positions.
Attach the brackets.
Attach the rail to the brackets.
Installation of the Motor
Unlock the motor.
he drive pulley hole.
Lock the motor.
Commissioning
Setting the End Limits
Switch on the power supply.
After the first Open or Close command, the motorized product will run at reduced speed to one end, then the other, to set the end stops.
Use & Maintenance
This drive is maintenance-free.
Open and Close Buttons
Press Open or Close to fully open or close the product.
Stop Function
While the product is moving, briefly press Stop — the product stops automatically.
DCT Wiring
| Wire | Description | Terminal |
|---|---|---|
| 1 | CCW (Open) NO Dry Contact | 4 |
| 2 | Stop – NO Dry Contact | 5 |
| 3 | Ground Common | 6 |
| CW (Close) NO Dry Contact |
Wire 100V to 240V
| Wire | Function | Color |
|---|---|---|
| 1 | Neutral | Blue |
| 2 | Live | Brown |
| 3 | Earth | Yellow / Green |
Control Buttons: Open • Stop • Close
Tool: DCT Setting Tool (Part: 9014599) Not Supplied
Tips & Recommendations for Installation
Troubleshooting
| Observation | Possible Cause | Solution |
|---|---|---|
| The motorized product does not operate. | Wiring is incorrect. | Check and reconnect power. |
| Control point not compatible. | Check compatibility and replace if necessary. |
Tips & Recommendations for Use
If the product still does not work, contact a motorization or home automation professional.
| Observation | Possible Cause | Solution |
|---|---|---|
| The motorized product does not operate. | Motor is in thermal protection mode. | Wait for the motor to cool down. |
Technical Data
| Specification | Value |
|---|---|
| Power Supply | 100V – 240V |
| Operating Temperature | 0°C to +60°C |
| Protection Rating | IP 30 |
| Safety Level | Class I |