Introduction
-
- TRO.Y2 is an IP Control gateway that allows 3rd party integration with shades and screens via PoE and RS232.
- TRO.Y2 allows advanced control options for all motor types including 485, RTS and Zigbee via its integration with wireless bridges.
- Compatible wireless bridges include LinkProZ, Helen, TaHoma Switch and TaHoma.
- Another feature allows TRO.Y2 to use handheld remotes and keypads to control any shade or screen.
- New builtin real-time clock, events and scenes allow for expanded control options.
Features
- Embedded commissioning software
- 485 programming
- Powered via PoE
- 4 segmented 485 bus line
- Single integration point for third-party automation systems over IP or RS232
- Compatible with SDN 2.0 (485)
- Works with Somfy Synergy™ API
- Advanced Lutron compatibility
- Din Rail mounting capability
- Built-in Real Time Clock
- Create Scenes and Events for any motor type(s)
INITIAL CONSIDERATIONS
- This is designed to be installed indoors, Rack or Din Rail mounted.
- If utilizing Janus, it should be in close proximity to the Janus units not exceeding 200' for each port(refer to pg. 9 for more info.).
- TRO.Y 2 has four 485 ports, in order to segment and improve 485 bus.
- When deploying the shades where ever possible its a best practice to divide the shades into 4 segments. This will improve performance and lower latency on commands.
With 32 shades, and 4 Janus units, the preferred method of wiring is 1 Janus per port or 8 shades per port.
INSTALLATION - CONNECTIONS
Step 1: Connecting Power
- TRO.Y 2 uses PoE for Power: Connect to PoE switch or included power injector. (PoE 802.3 - compatible with all versions of PoE AT/BT).
- TRO.Y 2 offers the ability to connect up to 4 segments utilizing the 485 ports, using CAT5e/6 cable.
- For the highest level of performance, each segment should not contain more than 64 shades (for a total of 256 shades).
- If you have a system that contains more than 256 shades, we recommend adding an additional TRO.Y.
- The colors above are based on TIA 568B termination.
- The Helen/ serial port data output (WHT/BLUE) is the transmit (TX) from TRO.Y.
- The Helen/serial port data input (GRN) is the receive (RX) from TRO.Y.
- The labels from the Helen port are from EIA561
High speed control port settings:
- BAUD rate - 4800 - 56k
- Control bits - 8
- Parity - None
- Stop bits - 1
Step 2: Connecting BUS Devices without Janus
All 4 ports can be used to connect 485 devices, however no Bus power is provided by TRO.Y 2.
Step 3: Connecting BUS Devices without Janus
PoE Connection provides 3rd party IP control, wireless control and connection to other TRO.Y 2s.
For issues, contact Screen Innovations:
Phone: 512.832.6939 Option 3
Website: www.screeninnovations.com