Step 1: TRO.Y Integration Settings
- Enter the TRO.Y GUI by typing its IP address into a browser
- Press the Integration Settings Button
Step 2: TRO.Y Integration Settings
- Scroll Down and select the SHOW button under the Telnet/Json Server Settings.
- Select the TCP option.
- Enter your User Name and Password.
- This can be anything, but it must match what is inputted into the C4 Gateway Driver.
- Press the Submit Button.
.
Step 3: Restart the TRO.Y
- Go to the System Settings at the top of the Screen
-
Scroll Down and press the Restart Button
- Then confirm the Restart
When the Control 4 Gateway driver is setup, you will see a "Good Connection" in the TRO.Y's Dashboards System Status.
Step 4: C4 Composer - Network Settings
- In the Connections tab under System Design, double-click the Screen Innovations Troy Gateway.
- Enter the TRO.Y's IP address and press Close.
.
- In the Gateway Driver you will see the Operational Mode show: OK
Step 5: C4 Composer - Adding Drivers
-
Search the Drivers for Screen Innovations, there will be 3 drivers to select and install and label.
- Screen Innovations Troy Gateway - (Install only one instance of this Driver)
- Screen Innovations Blind - (Install one driver for each individual shade in the system)
- Screen Innovations Blind Group - (Install one driver for each shade group in the system)
Download the latest versions of the drivers here
.
Step 6: C4 Composer - Gateway Driver
About the Control 4 Gateway Driver
- Enter the Gateway Username and Password used in the Telnet/Json Server Settings of the TRO.Y
- Select the ACTIONS tab and press the Discover Devices Button
Step 7: C4 Composer - Blind Driver
About the Blind and Blind Group Drivers
- In the Blind Name drop down, select the shade for this driver.
- Select the ACTIONS tab, and press the Measure Travel Time button.
- THIS IS REQUIRED FOR 2 WAY FEEDBACK
- This will move the shade to calculate the travel time, and will show in seconds.
Step 8: C4 Composer - Blind Group Driver
About the Blind and Blind Group Drivers
- In the Blind Group drop down, select the Shade Group (created in TRO.Y)
- In the Group Master Blind, select on shade in that group to be the Master, usually the largest shade of the group.
- Select the ACTIONS tab and press the Measure Travel Time Button.
- THIS IS REQUIRED FOR 2 WAY FEEDBACK
- This will move the shade group to calculate the travel time, and will show in seconds.