SDN Motor Configuration Software Using the USB Programming Cable
Screen Innovations
Step 1: Software and COM Port Setup
- Download and install the latest SDN Motor Configuration software as administrator when possible from: Download the Somfy SDN Motor Configuration Software here
- Connect the USB-Programming Cable to any USB port on your laptop
-
Open Device Manager from Windows Start menu
- Go to Ports and click to expand it
- Make note of the COM Port number listed for the RS485 port
Info: If RS485 Port is not listed under "Ports", you must install the driver for the USB-to-RS485 Adaptor. Download from: https://support.advantech-bb.com/download?product_model_name=BB-485USB9F-2W-LS#Driver
- Right click on the RS485 Port and click Properties
-
Click the Port Settings tab and confirm the settings are:
- Bits per second: 4800
- Data Bits: 8
- Parity: Odd
- Stop Bits: 1
- Flow Control: None
- Open the Somfy Digital Network™ (SDN) Motor Configuration Software from the Desktop icon or Windows Start menu
- Select the COM port at the top left of the window that you noted from Device Manager and click "Connect". You are now connected to the COM port
Warning: If no COM ports are listed in the dropdown, close the software, ensure USB cable is connected, then reopen. If still no COM port, reinstall the USB-Programming Cable driver. Ensure Motor Config is the only software running and no other software is using the COM port.
Step 2: Discovering Motors
Discover a Single Motor:
- Click the "Get Single Motor Address" button
- The Node ID of the motor found will populate the field under the Addressing section
Discover All Motors on an SDN System:
- Click the "Auto Discovery" button
- The Node IDs of all motors found will populate the field under the Motor Addresses section
Step 3: Setting Limits
Movement Controls:
- Up (Pulses) – Moves the motor up by the number of pulses specified in the field to the right
- Up (ms*10) – Moves the motor up by the number of milliseconds times 10 specified in the field to the right
- Down (Pulses) – Moves the motor down by the number of pulses specified in the field to the right
- Down (ms*10) – Moves the motor down by the number of milliseconds times 10 specified in the field to the right
Adjusting Limits:
- Send the motor to its Up or Down limit
- Select the "Limit Adjust" radio button
- A pop-up warning will appear about enabling Limit Adjust Mode; click OK
-
Adjust the chosen limit:
- [Higher] Enter "10", "20" or "50" in the top field and click Up (Pulses) or Up (ms*10) to adjust the limit slightly higher
- [Lower] Enter "10", "20", "50", etc., in the bottom field and click Down (Pulses) or Down (ms*10) to adjust the limit slightly lower
- Disconnect and reconnect the Motor Configuration Software, discover the motor, send it Up or Down, then send it to the adjusted limit to confirm the change has been set
Step 4: Resetting Motor and Alternate Limit Setting
Available Functions:
- Reset Motor(s) – Resets all the limits that are set on the motor
- Reverse Rotation – Sets the motor to run in the reverse direction
- Standard Rotation – Sets the motor to run in the standard direction
- Wink Motor – Jogs the motor up and down
- Set Up @ Current – Sets the upper limit to the current position that the motor is in
- Set Down @ Current – Sets the down limit to the current position that the motor is in
- Set Down @ – Sets the down limit at the pulse count entered in the box next to it
- Up (ms*10) – If the motor has no limits set, moves the motor up by the number of milliseconds specified in the box times 10
- Down (ms*10) – If the motor has no limits set, moves the motor down by the number of milliseconds specified in the box times 10
Reset Motor Procedure:
-
Select the "Reset Motor" radio button
- A pop-up warning will appear about enabling Reset Motor Mode; click OK
- Use the buttons under the Reset Motor section to adjust the motor accordingly
To Set Limits:
- Using the Up (ms*10) or Down (ms*10) buttons, move the screen to the desired upper limit, and press the "Set Up @ Current" button to save the upper limit
- Using the Up (ms*10) or Down (ms*10) buttons, move the screen to the desired lower limit, and press the "Set Down @ Current" button to save the lower limit
Tip: You can change the size of the increments by changing the number in the field next to the Up and Down (ms*10) buttons. This number can be between 10-255. Be careful not to use too large a number close to the top or lower limit of the screen to avoid damage to the screen.
Support Information
For issues, contact Screen Innovations:
- Phone: 512.832.6939 Option 3
- Website: www.screeninnovations.com